Industrial Electrical Safety & Energy Audits
Eliminate fire hazards, slash utility harmonic penalties, and ensure 100% CEA & CEIG regulatory compliance with certified non-invasive thermography, Class-A power quality logging, and earth resistance evaluations across Telangana, Andhra Pradesh, and South India.
Technical Audit Desk
Connect with our senior compliance and electrical testing engineers for custom scope scheduling.
Diagnostic Inspections That Protect Plant Assets
We employ calibrated, laboratory-grade instrumentation to detect insulation degradation, dangerous harmonic currents, and fire risks before catastrophic failures happen.
Electrical Safety & Fire Hazard Audits
Exhaustive walk-through audits benchmarked against IS 14489, National Electrical Code (NEC), and CEA safety rules. We inspect breaker sizing, protective grading, and arc-flash hazard zones.
- Breaker short-circuit breaking capacity verification
- Cable current-carrying derating factor assessment
- Hazardous area flameproof (FLP) ingress compliance
Live Infrared Thermography Scans
Real-time non-invasive infrared imaging under live plant loads to detect high-resistance joints, overloaded phase contacts, unbalanced feeder currents, and failing breaker jaws.
- High-resolution Delta-T thermal anomaly mapping
- Side-by-side visual and radiometric infrared captures
- Prioritized corrective rectification matrix (Critical to Low)
Power Quality & Harmonic Logging
Class-A power quality recording measuring Total Harmonic Distortion (THD up to the 50th harmonic), voltage sags, power factor dips, and transient spikes generated by nonlinear VFD loads.
- IEEE 519 compliance verification for grid connection
- Neutral current harmonic amplification analysis
- Active Harmonic Filter (AHF) sizing and recommendations
Earthing & Soil Resistivity Surveys
Verification of transformer neutral grounding, equipment body earthing loops, electronic clean earths, and Wenner 4-pin soil resistivity calculations according to IS 3043 and IEEE 80.
- Fall-of-potential individual pit resistance checks
- Interconnecting earthing grid mesh continuity testing
- Step and touch potential safety verification
CEIG Regulatory Gap Analysis
Structured audit to prepare your plant for statutory Chief Electrical Inspectorate to Government (CEIG) approvals, annual inspection clearances, and safety licensing renewals.
- Verification of Single Line Diagrams (SLD) vs site layout
- Safety clearance, rubber mat & danger signage audits
- Relay calibration certificates & protective lockout audits
Industrial Energy Efficiency Audits
Detailed assessment of plant energy sinks: transformer no-load/full-load losses, oversized motor loading, compressor air leakage audits, and power factor penalty elimination.
- Compressed air specific power consumption (SPC) tests
- Motor load factor optimization (IE3 / IE4 retrofits)
- APFC capacitor step optimization to avoid discom fines
Audit Instrumentation & Governing Codes
All assessments utilize calibrated, traceable diagnostic tools conforming to international norms.
| Audit Module | Governing Standards | Calibrated Testing Equipment Deployed | Key Parameters Analyzed | Standard Deliverable |
|---|---|---|---|---|
| Electrical Safety Audit | IS 14489 / CEA Regs 2010 | Digital Loop Impedance Meter, Insulation Megger | Fault loop impedance, RCD trip times, cable derating | Safety Hazard Matrix & Corrective BoQ |
| Infrared Thermography | ASTM E1934 / ISO 18434 | Fluke / FLIR High-Resolution Radiometric Camera | Delta-T temperature gradients, thermal reflections | Thermal Photo Logbook with Priority Tags |
| Power Quality & Harmonics | IEEE 519-2022 / IEC 61000-4-30 | Class-A Three-Phase Power Quality Analyzer | THD-V, THD-I, Crest Factor, Voltage Sag/Swell, PF | Harmonic Mitigation & Filter Sizing Report |
| Earthing & Soil Resistivity | IS 3043-2018 / IEEE 80 | Digital 4-Terminal Earth Resistance Tester | Individual pit resistance, grid continuity, soil Ohm-m | Earth Pit Numbered Test Certificates |
| CEIG Statutory Audit | Indian Electricity Rules (IER) | Secondary Current Injection Test Set, Calipers | Relay coordination curves, clearances, interlocks | CEIG Statutory Compliance Dossier |
| Energy Performance Audit | BEE Guidelines / ISO 50001 | Ultrasonic Flow Meter, Air Leak Detector, Lux Meter | kWh/ton metrics, specific power, lux distribution | Energy Conservation Measure (ECM) Business Case |
Our 4-Stage Diagnostic Methodology
A rigorous engineering process that turns complex raw telemetry into clear, actionable plant improvements.
Preliminary Review
Analysis of Single Line Diagrams (SLDs), past electricity bills, connected load schedules, and historical breakdown logs.
On-Site Diagnostic Testing
Live infrared thermal scans under peak production, 24/7 or 7-day power quality logging, earth pit testing, and physical inspection.
Engineering Analysis
Processing thermal radiometric data, calculating harmonic spectrum curves against IEEE 519 limits, and fault risk grading.
Dossier Handover & BoQ
Delivery of executive summary, photographic evidence, statutory sign-off certificates, and a prioritized turnkey remediation BoQ.
Frequently Asked Questions
Common questions from plant directors, maintenance heads, and safety officers.
Identify Electrical Risks Before They Cause Plant Outages or Fires
Schedule a certified electrical safety, thermography, or power quality audit for your plant. Our certified diagnostic engineers will outline the testing protocol and quotation.