Supply Desk 9390021173
Get a Quote
Skip to content
IS/IEC 61439 Type-Tested | CEIG Statutory Clearance
Industrial Switchgear & Power Distribution

Engineered HT & LT Switchgear Assemblies for Industrial Substations & Motor Centers.

Thibstas Industrial engineers, fabricates, tests, and commissions custom High Tension (11kV to 33kV VCB & GIS) and Low Tension (415V up to 6300A) switchboards. Designed to Form 4b internal segregation with CPRI type-tested short-circuit withstand up to 100kA, complete with turnkey CEIG inspection approvals.

Voltage Range 11kV-33kV HT / 415V LT
Fault Rating Up to 100kA Icu (1s / 3s)
Internal Safety Form 4b Arc-Contained
Direct WhatsApp RFQ

Switchgear Sizing & BOQ Quote

Select your switchgear requirement tag below or enter your single-line diagram parameters for rapid technical quote delivery.

Quick Select Requisition Type:

Engineering department transmission. Direct engineer engagement.

Turnkey Scope Comprehensive Switchgear Engineering from Primary HT Incomer to Motor Terminal.
Fault Levels 26.3kA to 100kA Icu. Calculated per busbar thermal & electrodynamic stress.
Segregation Standard Form 3b & Form 4b. Fully isolated busbar, unit & cable chambers.
Compliance IS/IEC 61439 & CEIG. Pre-tested with factory routine & type test certificates.
Engineered Product Range

Industrial Switchgear Panels We Design & Supply.

Each assembly is fabricated in 2.0mm/2.5mm CRCA sheet steel, 7-tank surface treated, pure polyester powder coated (RAL 7032 / 7035), and wired with flame-retardant tri-rated copper conductors.

11kV Vacuum Circuit Breaker HT Switchgear Panel
11kV / 22kV / 33kV HT
Primary Medium Voltage

Medium Voltage (HT) VCB & GIS

Indoor metal-clad vacuum circuit breaker (VCB) panels and SF6 gas-insulated switchgear (GIS). Features motorized draw-out cassettes, safety shutters, integral earthing switch, and numerical protection relays (50/51/50N/51N/87T).

630A to 3150A 26.3kA / 31.5kA (3s) IEC 62271-200
LT Power Control Center PCC Panel with Air Circuit Breakers
Up to 6300A 415V
Low Voltage Main Distribution

Power Control Centers (PCC Panels)

Main plant distribution switchboards receiving transformer secondary feeds. Equipped with 3-pole or 4-pole draw-out Air Circuit Breakers (ACB), microprocessor protection releases (LSI/LSIG), busbar couplers, and metering centers.

800A to 6300A ACB 50kA – 100kA Icu (1s) Form 4b Separation
Intelligent Motor Control Center iMCC Draw-out Compartments
Draw-out / Fixed Modules
Drive & Process Control

Motor Control Centers (MCC & iMCC)

Fully compartmentalized motor control switchboards with draw-out starter buckets. Houses DOL, Star-Delta, solid-state soft starters, and integrated VFD drives with networked communication (Profinet/Modbus) for DCS supervisory control.

0.75kW to 315kW Feeders Type-2 Coordination IEC 60947-4-1
Thyristor-Switched APFC Capacitor Panel with Detuned Reactors
kVAr Power Factor Correction
Power Quality & Energy Efficiency

APFC & Harmonic Filter Panels

Automatic Power Factor Correction panels engineered with microprocessor APFC relay controllers, heavy-duty MPP/gas capacitors, and 7% or 14% copper-wound detuned harmonic reactors to eliminate resonance and maintain unity power factor.

50 kVAr to 1200 kVAr Thyristor / Contactor Switched 0.99 PF Maintenance
DG Auto-Synchronizing and Load Sharing Switchgear
Multi-Generator Control
Emergency Backup & Paralleling

DG Synchronization & AMF Panels

Automated generator synchronizing and load-sharing switchboards. Manages multiple diesel generator sets operating in parallel with the utility grid, incorporating motorized 4-pole changeovers, reverse power relays, and automatic load shedding.

250kVA to 3000kVA Paralleling Deep Sea / Woodward / Deif Auto Load Shedding
Sandwich Busbar Trunking System Aluminium and Copper
400A to 6300A Busduct
High Current Power Feeds

Sandwich Busbar Trunking (BBT)

Compact sandwich-construction copper and aluminium busbar trunking for transformer-to-PCC connections, generator tails, and vertical riser risers in multi-story industrial facilities. Certified for low voltage drop and IP55/IP66 weatherproof rating.

Aluminium / Copper Conductors Class-F Epoxy Insulation Plug-In Tap-Off Boxes
Engineering Reference

Switchgear Sizing & Electrical Standards Matrix.

Engineering parameters for industrial switchboards fabricated in compliance with IS/IEC 61439-1 & 2, IEC 62271-200, and National Electrical Code standards.

Equipment CategoryRated Voltage & InsulationContinuous Current & Fault RatingEnclosure Ingress & Internal FormCompliance Standard & Tier-1 OEMs
11kV / 22kV / 33kV VCB Switchgear11kV, 22kV, 33kV (Up to 75kV / 170kV BIL)630A to 3150A; 26.3kA / 31.5kA / 40kA for 3 secIP4X / IP5X; Loss of Service LSC-2B, Partition PMIEC 62271-200; Schneider, ABB, Siemens, L&T
Power Control Center (PCC Panels)415V AC, 3-Phase 4-Wire (1000V Ui)800A to 6300A; 50kA, 65kA, 85kA, 100kA for 1 secIP54 / IP55; Form 4b metallic segregated chambersIS/IEC 61439-1 & 2; Schneider, L&T, ABB, Siemens
Motor Control Center (MCC / iMCC)415V AC (DOL, Star-Delta, Soft Starter, VFD)Main Bus 800A-3200A; Feeders 9A to 630A; 50kA 1sIP54; Fully draw-out modular cassettes (Form 3b/4b)IS/IEC 60947-4-1; L&T, Schneider, Siemens, Eaton
Automatic Power Factor Correction (APFC)440V / 480V / 525V Heavy Duty Capacitors50 kVAr to 1500 kVAr; 7% or 14% detuned copper reactorIP42 / IP52 with forced ventilation cooling fansIEC 61921 / IS 13340; Epcos, Schneider, L&T
DG Synchronization & AMF Panels415V AC; Automatic paralleling controllerUp to 4 x 2500kVA DG sync; 65kA fault levelIP54 sheet steel enclosure; Form 3b compartmentalizedIS/IEC 61439; Deep Sea, Woodward, Deif controllers
Sandwich Busbar Trunking (BBT)Up to 1000V AC; 50/60 Hz400A to 6300A (Aluminium or Copper conductors)IP55 indoor / IP66 outdoor weatherproof; Class-F insulationIEC 61439-6; Schneider, L&T, Siemens, Legrand
Safety & Reliability Engineering

Form 4b Segregation & Internal Arc Containment.

Plant downtime and personnel safety depend on internal design rigor. Every Thibstas switchboard is engineered with compartmentalized barriers to prevent fault propagation.

Form 4b Complete Segregation

Main horizontal and vertical busbars, individual functional breaker modules, and respective external cable termination boxes are isolated behind metallic barriers.

Internal Arc Containment

Engineered pressure relief flaps on switchboard roof vent ionized gases upward during an internal flashover, complying with IEC TR 61641 safety criteria.

Mechanical & Key Interlocks

Castell mechanical interlocks and electrical door limit interlocks guarantee doors cannot be opened unless the incoming breaker is isolated and grounded.

Insulated Electro-Plated Busbars

Electrolytic copper and aluminium busbars are tin/silver plated at joints and sleeved with 33kV-grade radiation cross-linked heat-shrinkable polyolefin sleeves.

OEM Integration

Authorized Tier-1 Switchgear Brand Partnerships.

We build custom panels incorporating genuine type-tested OEM breakers, relays, and components, ensuring factory warranties and spare parts availability for decades.

Schneider Electric MasterPact MTZ, TeSys & Prisma Architecture
L&T Electrical Omega ACBs, U-Power & Super-A Contactors
Siemens Sivacon S8, 3WL/3VA Breakers & Sirius
ABB MNS System, Emax 2 & Tmax XT Breakers
Eaton Capitole 40, NZM Breakers & Moeller Starters
Legrand DMX3 ACBs, DPX3 MCCBs & XL3 Enclosures
Turnkey Project Delivery

From Single Line Diagram (SLD) to CEIG Energization.

Thibstas Industrial manages the entire project lifecycle, ensuring zero coordination gaps between engineering design, panel fabrication, testing, and statutory licensing.

Engineering Lifecycle

Engineering, Factory Acceptance Testing (FAT) & Site Commissioning.

Every switchboard undergoes 100% factory verification before dispatch: high-voltage dielectric withstand, secondary injection protection testing, contact resistance measurement, and interlocking logic simulation.

Short-Circuit Calculations Relay Coordination Studies Factory Acceptance Test (FAT) CEIG Clearance Liaison
01

SLD Analysis & General Arrangement (GA) Design

We review your single-line diagram, calculate busbar thermal cross-sections, prepare GA layout drawings, foundation base plans, and obtain client approval.

02

CNC Fabrication & Factory Acceptance Testing (FAT)

Panels are fabricated with 2.0mm/2.5mm CRCA sheet steel, 7-tank powder coated, wired, and subjected to complete FAT client witness testing at our works.

03

Site Erection, Testing & CEIG Charging

Field engineers handle switchroom placement, busbar torqueing, megger & Hipot testing, relay injection verification, and CEIG statutory charging approval.

Technical FAQ

Frequently Asked Questions on Industrial Switchgear.

Authoritative engineering answers regarding segregation standards, CPRI certification, CEIG statutory compliance, and breaker retrofits.

Under IS/IEC 61439-2, Form 3b separates the main busbars from functional units (circuit breakers/feeders), with terminations for external conductors separated from the busbar, but allows terminations for functional units to be in the same compartment as the units. Form 4b provides complete internal segregation: the busbar, functional units, and individual cable terminations for every feeder are housed in isolated metal compartments. This enables maintenance engineers to terminate or service any single feeder without de-energizing adjacent live units or risking accidental arc flash contact.
Yes. Our standard switchgear enclosures, busbar structures, and breaker arrangements are type-tested as per IS/IEC 61439-1 & 2 for short-time withstand current (up to 100kA for 1s / 50kA for 3s), temperature rise limits, dielectric strength, degree of ingress protection (IP54/IP55), and internal arc fault containment in accordance with IEC TR 61641.
Yes. Every switchgear installation project executed by Thibstas Industrial includes full CEIG/CEA statutory documentation support: Single Line Diagrams (SLD), fault level calculations, protection relay grading curves, equipment layout plans, earthing mesh calculations, and liaison with statutory electrical inspection authorities through pre-commissioning inspection and final charging approval.
We engineer busbar systems in both high-conductivity electrolytic copper (99.9% IACS, current density typically 1.2 to 1.6 A/sq.mm) and electrical-grade E91E aluminium alloy (current density 0.8 to 1.0 A/sq.mm). Copper is recommended for space-constrained switchrooms and heavy vibration environments, while aluminium offers significant cost optimization for high-ampere PCC runs (up to 4000A) when designed with proper silver-plated bimetallic jointing.
Yes. We offer turnkey ACB retrofit solutions for legacy switchboards (replacing phased-out breakers from English Electric, Alstom, or older Schneider/L&T series). We engineer custom copper busbar adapter links, cradle transition plates, and auxiliary wiring harnesses to install modern microprocessor-based ACBs (e.g., Schneider MasterPact MTZ, L&T Omega) during planned maintenance shutdowns with zero modification to the main panel frame.
Turnkey Engineering Engagement

Planning a Substation, Plant Expansion, or Switchgear Modernization?

Connect with our electrical switchgear engineering team. Share your Single Line Diagram (SLD) or Bill of Quantities (BOQ) for rapid busbar sizing, GA layout drafting, and an itemized commercial proposal.