Supply Desk 9390021173
Get a Quote
Skip to content
HT & LT Armored Power Cables • FRLS & Fire Survival • IS 7098 / IS 1554 Certified

Industrial Power, Control & Instrumentation Cables

High-voltage 11kV/33kV XLPE armored transmission cables, 1.1kV LT heavy distribution feeders, shielded signal cables, and certified fire-survival lines. Thibstas Industrial supplies cut-to-length factory-sealed drums from authorized tier-1 manufacturers (Polycab, Havells, KEI) with verified test certificates and site pre-commissioning testing.

Heavy Industrial Armored Power Cables on Cable Tray System
Certified Tier-1 Supply

Heavy Armored XLPE Power Feeders

Direct supply for substations, MCC panels, and motor drives

1.1kV to 33kV
HT & LT Voltage Class Spectrum
IS 7098 • IS 1554
BIS, IEC & CPRI Type-Tested
FRLS • FS 950°C
Fire-Survival (BS 7846 / IEC 60331)
Authorized Tier-1
Polycab • Havells • KEI • Finolex
Product Classification

Industrial Cable Categories & Engineering Applications

Engineered for continuous heavy duty-cycles in substations, chemical processing, manufacturing plants, and utility trenches.

HT XLPE Armored Power Cables 3.3kV to 33kV

HT XLPE Armored Power Cables

High-tension triple-extruded dry-cured XLPE insulated power cables engineered for primary grid substations and transformer interconnects.

  • Conductors: Stranded compact aluminum or electrolytic copper (IS 8130)
  • Semi-conducting conductor and insulation screen
  • Galvanized steel flat strip or round wire armor
  • Tested to IS 7098 (Part 2) & IEC 60502-2
Electrical control Panels 1.1kV Rating

LT Power & Distribution Cables

1.1kV cross-linked polyethylene (XLPE) or PVC insulated armored feeders for Main PCCs, Motor Control Centers, and heavy production machinery.

  • Configuration: 1-Core, 2-Core, 3-Core, 3.5-Core & 4-Core
  • Sizes: 1.5 sq.mm up to 1000 sq.mm aluminum/copper
  • Heavy FRLS PVC outer sheath resistant to moisture & oils
  • Tested to IS 7098 (Part 1) & IS 1554 (Part 1)
Control and Instrumentation Cables Screened / Shielded

Control & Instrumentation Cables

Multi-core and multi-pair screened cables designed to transmit low-voltage analog signals, 4-20mA loops, and digital PLC I/O telemetry without noise.

  • Individual and overall aluminum mylar tape with drain wire
  • High common-mode noise rejection in VFD-heavy plants
  • Core configurations from 2 cores up to 61 cores
  • Tinned or bare copper conductors (Class 2 / Class 5)
Fire Survival Low Smoke Zero Halogen Cables Circuit Integrity

Fire Survival (FS) & FRLS-LSZH Cables

Emergency circuit cables engineered to maintain critical power to fire pumps, smoke extraction fans, and emergency lighting during active building fires.

  • Glass mica tape fire barrier operating up to 950°C for 3 hours
  • Low Smoke Zero Halogen (LSZH) non-toxic sheath (IEC 60754)
  • Tested to BS 7846 Category F2 & IEC 60331
  • Essential for infrastructure tunnels, pharma, and high-rises
Engineering Construction

Anatomy of an Industrial Heavy-Armored Cable

Every layer in our industrial cables is engineered for mechanical toughness, thermal endurance, and moisture resistance to withstand harsh factory and subterranean utility environments.

01
Conductor (EC Grade Aluminum or Copper)

High-conductivity Class 2 stranded compacted conductor compliant with IS 8130, ensuring minimal I²R transmission losses.

02
XLPE Primary Insulation

Cross-linked polyethylene rated for 90°C continuous operation and 250°C short-circuit thermal limit.

03
Inner Sheath (Extruded PVC / LSZH)

Provides a smooth, protective bedding cushion over the assembled cores prior to armoring.

04
Galvanized Steel Armor (GSWA / GSFA)

Heavy mechanical armor guarding against crushing forces, sharp trench aggregate, and rodent damage.

05
FRLS Outer Jacket

UV-stabilized flame-retardant outer sheath with high oxygen index (>29%) resistant to chemical fumes and water.

Industrial Cable Cross-Section and Switchboard Terminations
Technical Metrics

Industrial Cable Specifications & Standards Matrix

Comprehensive engineering parameters comparing voltage ratings, insulation materials, armoring, and compliance codes.

Cable DomainVoltage GradeConductor MaterialInsulation & TempArmor & SheathGoverning Standards
HT Armored Power3.3kV up to 33kV (UE/E)Stranded Compact Aluminum / CopperDry-Cured XLPE (90°C / 250°C)Round Steel Wire / Flat Strip + FRLS PVCIS 7098 (Part 2), IEC 60502-2
LT Armored Power650V / 1100V (1.1kV)Electrolytic Aluminum / Annealed CopperXLPE / Heat-Resistant PVCGalvanized Steel Strip / Wire + FRLSIS 7098 (Part 1), IS 1554 (Part 1)
Control Cables1100VHigh-Conductivity Bare CopperPVC Type A / XLPEGI Wire / Strip Armored + FRLSIS 1554 (Part 1), IEC 60227
Instrumentation300V / 500V / 1100VTinned / Bare Annealed CopperPolyethylene / PVC / XLPEOverall Al-Mylar Screen + Drain WireBS 5308 (Part 1 & 2), EN 50288-7
Fire Survival (FS)1100VStranded Plain Annealed CopperMica Glass Tape + XLPELow Smoke Zero Halogen (LSZH)BS 7846 Cat F2, IEC 60331 (950°C / 3h)
Execution Methodology

4-Stage Sourcing, Quality Inspection & Site Delivery

We guarantee verified drum lengths, authentic factory test certificates, and on-site testing to eliminate contractor installation failures.

Stage 01

Cable Schedule & Sizing Audit

Current carrying capacity verification, derating factors (soil temp, grouping, depth), and fault current withstand calculations.

Stage 02

Authorized OEM Sourcing & FAT

Direct manufacturing allocation with Polycab, Havells, or KEI, complete with Mill Test Certificates (MTC) and routine factory testing.

Stage 03

Cut-to-Length Drum Logistics

Factory drum cutting matching project pull schedules, eliminating intermediate cut wastage and site splicing bottlenecks.

Stage 04

On-Site Testing & Handover

Pre-laying insulation resistance (Megger up to 5kV), conductor continuity, VLF Hipot testing, and documentation for CEIG clearance.

Frequently Asked Questions

Industrial Cables Technical & Sourcing Insights

Technical and commercial answers for project electrical engineers, procurement heads, and EPC managers.

What is the difference between XLPE and PVC insulation for industrial power cables? +

Cross-Linked Polyethylene (XLPE) operates at higher continuous conductor temperatures (90°C vs 70°C for PVC) and short-circuit temperatures (250°C vs 160°C). This gives XLPE cables higher current-carrying capacity, lower dielectric losses, higher moisture resistance, and longer service life for industrial motor and substation feeds.

When should galvanized round wire armor be specified instead of flat strip armor? +

Round wire armor (GSWA) provides superior tensile pull strength and longitudinal flexibility, making it mandatory for vertical shaft risers, deep underground bore pulling, and high mechanical pulling stress. Flat strip armor (GSFA) provides high surface coverage for horizontal cable tray runs and duct banks where crushing resistance is needed.

What standards do your Fire Survival (FS) and FRLS cables comply with? +

Our Fire Survival (FS) cables feature mica tape insulation barriers compliant with BS 7846 and IEC 60331, maintaining circuit integrity for 3 hours under 950°C flame exposure. Flame Retardant Low Smoke (FRLS) outer sheaths comply with IS 7098, with critical oxygen index > 29% and low acid gas emission (< 20%).

Which cable manufacturing brands does Thibstas Industrial supply? +

We supply Tier-1 authorized cable brands including Polycab, Havells, KEI Industries, Finolex, and RR Kabel. Every dispatched drum includes original manufacturer Mill Test Certificates (MTC), CPRI type-test reports, and batch warranty documentation.

Do you provide cut-to-length custom cable drum logistics and on-site testing? +

Yes. We supply factory-sealed drums cut precisely to your project's scheduled pull lengths to eliminate scrap waste. Our field engineering team can also conduct on-site insulation resistance (Megger up to 5kV) and VLF high-potential (Hipot) testing prior to energization.

Need a Competitive Quote for Your Project Cable Schedule?

Share your cable schedule, conductor sizing, or Bill of Quantities (BOQ). Our procurement desk will provide itemized pricing with manufacturer test certificates and guaranteed site delivery timelines.

Sales & Procurement Desk: +91 8143865751 (Mr. Aditya Datta) • Projects: +91 9492829072